Parsu Veera, U. ; Patwardhan, A. W. ; Joshi, J. B. (2001) Measurement of gas hold-up profiles in stirred tank reactors by gamma ray attenuation technique Chemical Engineering Research and Design, 79 . pp. 684-688. ISSN 0263-8762
Full text not available from this repository.
Abstract
Gas hold-up is one of the most important hydrodynamic characteristics that is needed for performance estimation, design and scale-up of reactors. The performance of large-scale reactors can be reliably evaluated by measuring the gas hold-up in such reactors. In the present work, local gas hold-up in an industrial reactor has been measured with the help of gamma ray tomography. Based on these measurements, an empirical equation has been proposed for the estimation of the gas hold-up distribution. The proposed equation has been validated by comparison with laboratory scale data.
Item Type: | Article |
---|---|
Source: | Copyright of this article belongs to Institution of Chemical Engineers. |
ID Code: | 93022 |
Deposited On: | 08 Jun 2012 08:39 |
Last Modified: | 08 Jun 2012 08:39 |
Repository Staff Only: item control page