Kumar, Anish ; Rajkumar, K. V. ; Palanichamy, P. ; Jayakumar, T. ; Patankar, V. H. ; Joshi, V. M. ; Lande, B. K. ; Chellapandian, R. ; Kasiviswanathan, K. V. ; Baldev Raj, (2005) Development and application of C - scan ultrasonic facility BARC Newsletter, 285 . pp. 49-58. ISSN 0976-2108
|
PDF
- Publisher Version
478kB |
Abstract
This paper presents the in-house development and application of a C-scan ultrasonic facility ULTIMA 200M2 at the Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam, carried out in collaboration with the Electronics Division, Bhabha Atomic Research Centre (BARC), Mumbai. The paper describes various constituents of the system developed and also highlights the typical results obtained using this system, including bond integrity assessment of explosive welds and imaging of fuel sub-assembly heads of the Fast Breeder Test Reactor. The system has also been used for imaging both the sides of a one rupee Indian coin. All the finer details of the coin could be extracted, demonstrating the resolution capabilities of the system.
Item Type: | Article |
---|---|
Source: | Copyright of this article belongs to Bhabha Atomic Research Centre, Library & Information Services. |
ID Code: | 90600 |
Deposited On: | 11 May 2012 07:36 |
Last Modified: | 19 May 2016 04:44 |