Comparison of hydrodynamics and mass transfer in airlift and bubble column reactors using CFD

van Baten, J. M. ; Krishna, R. (2003) Comparison of hydrodynamics and mass transfer in airlift and bubble column reactors using CFD Chemical Engineering & Technology, 26 (10). pp. 1074-1079. ISSN 0930-7516

Full text not available from this repository.

Official URL: http://onlinelibrary.wiley.com/doi/10.1002/ceat.20...

Related URL: http://dx.doi.org/10.1002/ceat.200301796

Abstract

Computational Fluid Dynamics (CFD) is used to compare the hydrodynamics and mass transfer of an internal airlift reactor with that of a bubble column reactor, operating with an air/water system in the homogeneous bubble flow regime. The liquid circulation velocities are significantly higher in the airlift configuration than in bubble columns, leading to significantly lower gas holdups. Within the riser of the airlift, the gas and liquid phases are virtually in plug flow, whereas in bubble columns the gas and liquid phases follow parabolic velocity distributions. When compared at the same superficial gas velocity, the volumetric mass transfer coefficient, kLa, for an airlift is significantly lower than that for a bubble column. However, when the results are compared at the same values of gas holdup, the values of kLa are practically identical.

Item Type:Article
Source:Copyright of this article belongs to John Wiley and Sons.
Keywords:Bubble columns; CFD; Hydrodynamics; Mass transfer
ID Code:65428
Deposited On:17 Oct 2011 03:18
Last Modified:17 Oct 2011 03:18

Repository Staff Only: item control page