Steady state stress analysis of centrifugal fan impellers

Ramamurti, V. ; Balasubramanian, P. (1987) Steady state stress analysis of centrifugal fan impellers Computers & Structures, 25 (1). pp. 129-135. ISSN 0045-7949

Full text not available from this repository.

Official URL: http://www.sciencedirect.com/science/article/pii/0...

Related URL: http://dx.doi.org/10.1016/0045-7949(87)90224-0

Abstract

Cyclic symmetric structures such as centrifugal fan impellers are considered in this paper. One of the identical sectors is chosen for the finite element analysis. A triangular plate element is employed. The stiffness and load matrices are obtained in cylindrical coordinates. The displacements are obtained using a modified submatrices elimination scheme. The efficiency of this scheme is discussed. Impeller stresses are calculated and checked with the results obtained using a strain gauge technique.

Item Type:Article
Source:Copyright of this article belongs to Elsevier Science.