Sawant, S. B. ; Pangarkar, V. G. ; Joshi, J. B. (1979) Gas hold-up and mass transfer characteristics of packed bubble columns The Chemical Engineering Journal, 18 (1). pp. 143-149. ISSN 0300-9467
Full text not available from this repository.
Official URL: http://www.sciencedirect.com/science/article/pii/0...
Related URL: http://dx.doi.org/10.1016/0300-9467(79)80024-6
Abstract
The fractional gas hold-up, effective interfacial area a and the liquid side mass transfer coefficient kLa were obtained from 100 and 200 mm i.d. packed bubble columns using wire gauze packings. The values of a and kLa were measured using chemical methods. Two modes of operation were studied: (i) semi-continuous and (ii) continuous counter-current. The gas and liquid velocities were varied in the ranges 20 - 300 mm/s and 1 - 5 mm/s, respectively. The values of a and kLa were found to be in the ranges 80 - 160 m2/m3 and 0.04 - 0.09 s−1, respectively. The performance of the wire gauze packings is compared with that of conventional packings.