Investigations on cooling with forced flow of He II. Part 1

Srinivasan, R. ; Hofmann, A. (1985) Investigations on cooling with forced flow of He II. Part 1 Cryogenics, 25 (11). pp. 641-651. ISSN 0011-2275

Full text not available from this repository.

Official URL: http://www.sciencedirect.com/science/article/pii/0...

Related URL: http://dx.doi.org/10.1016/0011-2275(85)90120-1

Abstract

A test apparatus is described for studying heat transfer to flowing subcooled He II. A fountain pump was used to generate the flow. Measurements on subcooled He II at 1 bar are reported in this Paper. The Gorter-Mellink constant and the critical heat flux were measured and compared with values reported in the literature. The mass flow rate of He II was measured as a function of the heater power on the fountain pump and correlated with the temperature drop across the fountain pump. The temperature distribution was measured along a 1 m long test section with and without He II flow and was found to be in agreement with a one-dimensional model calculation. The possibility of using a self-sustained flow of He II generated by a fountain pump to remove heat in a test section is discussed.

Item Type:Article
Source:Copyright of this article belongs to Elsevier Science.
Keywords:He II; Forced Flow