Calculation of antibody and antigen concentrations from ELISA data using a graphical method

Raghava, G. P. S. ; Joshi, A. K. ; Agrewala, J. N. (1992) Calculation of antibody and antigen concentrations from ELISA data using a graphical method Journal of Immunological Methods, 153 (1-2). pp. 263-264. ISSN 0022-1759

[img]
Preview
PDF - Publisher Version
97kB

Official URL: http://linkinghub.elsevier.com/retrieve/pii/002217...

Related URL: http://dx.doi.org/10.1016/0022-1759(92)90330-V

Abstract

A graphical method for determining the concentration of either the antibody or the antigen from ELISA data is presented in the form of a GWBASIC program. In the program, ELISAEQ, optical densities (OD) obtained from a 96-well ELISA plate can be input either directly by interfacing a microplate reader to the computer or manually. The program uses standard sample data, and selects the semilogarithmic linear range. Over this range, a least-squares method is used to determine the concentrations of interest. In addition, a hyperbolic interpolation formula is derived over the entire range for estimating the antibody or antigen concentration of the unknown samples whose OD is beyond the linear range.

Item Type:Article
Source:Copyright of this article belongs to Elsevier Science.
ID Code:43089
Deposited On:09 Jun 2011 12:58
Last Modified:18 May 2016 00:11

Repository Staff Only: item control page