Intensity ratio of the Raman lines in diamond

Krishnan, R. S. ; Narayanan, P. S. (1950) Intensity ratio of the Raman lines in diamond Proceedings of the Indian Academy of Sciences, Section A, 32 (5). pp. 352-356. ISSN 0370-0089

[img]
Preview
PDF - Publisher Version
653kB

Official URL: http://www.ias.ac.in/j_archive/proca/32/5/352-356/...

Related URL: http://dx.doi.org/10.1007/BF03170852

Abstract

The relative intensities of the Raman lines in diamond have been studied by the spectrophotometric method, outlined in an earlier communication, using an ultra-violet Spekker photometer in conjunction with a medium quartz spectrograph. The values obtained for the fundamental oscillation, 1332 cm-1 are:- IStokes/Ianti-Stokes=426 IFundamenial/IOctave=270 confirming thereby the dependence of the intensity of a Raman line on the fourth power of the emission frequency.

Item Type:Article
Source:Copyright of this article belongs to Indian Academy of Sciences.
ID Code:30527
Deposited On:23 Dec 2010 13:24
Last Modified:17 May 2016 13:09

Repository Staff Only: item control page