Diagnostics of direct CT - PT contact of the coolant channels of PHWRs

Moorthy, R. I. K. ; Sinha, J. K. ; Rama Rao, A. ; Sinha, S. K. ; Kakodkar, Anil (1995) Diagnostics of direct CT - PT contact of the coolant channels of PHWRs Nuclear Engineering and Design, 155 (3). pp. 591-596. ISSN 0029-5493

Full text not available from this repository.

Official URL: http://linkinghub.elsevier.com/retrieve/pii/002954...

Related URL: http://dx.doi.org/10.1016/0029-5493(95)00975

Abstract

It has now been realised that the garter springs which maintain the gap between the pressure tube (PT) and calandria tube (CT) of a PHWR can get displaced significantly from their deign position in many channels. It has also been recognised that the large unsupported span of the PT restricts the life of the channel due to premature contact of the PT with the CT making it susceptible to delayed hydrogen cracking. This paper reports the details of a non-intrusive diagnostic technique based on vibration measurement for detecting the contacting channels.

Item Type:Article
Source:Copyright of this article belongs to European Nuclear Society.
ID Code:15815
Deposited On:13 Nov 2010 12:29
Last Modified:20 Feb 2011 16:28

Repository Staff Only: item control page