Acute effects of chewing tobacco on coronary microcirculation and hemodynamics in habitual tobacco chewers

Thakran, Vikas ; Ramakrishnan, Sivasubramanian ; Verma, SunilKumar ; Shetkar, Sudhir ; Seth, Sandeep ; Bhargava, Balram (2015) Acute effects of chewing tobacco on coronary microcirculation and hemodynamics in habitual tobacco chewers Journal of the Practice of Cardiovascular Sciences, 1 (2). pp. 138-142. ISSN 2395-5414

[img]
Preview
PDF - Other
461kB

Official URL: http://www.j-pcs.org/article.asp?issn=2395-5414;ye...

Related URL: http://dx.doi.org/10.4103/2395-5414.166316

Abstract

Background: Long-term adverse cardiovascular effects of smokeless tobacco are well established, however, the effect of chewing tobacco on coronary microcirculation and hemodynamic have not been studied. We intended to analyze the acute effect of chewing tobacco on coronary microcirculation and hemodynamics in habitual tobacco chewers with stable coronary artery disease undergoing elective percutaneous coronary intervention (PCI). Materials and Methods: We prospectively enrolled seven habitual tobacco chewers with stable coronary artery disease with single vessel disease or double vessel disease satisfying the criteria for elective PCI. Patients were instructed to keep 1 g of crushed dried tobacco leaves in the mouth after a successful PCI. Lesion in last stented vessels was evaluated for fractional flow reserve (FFR), coronary flow reserve (CFR), and index of microcirculatory resistance (IMR) post-PCI, after 15 min and 30 min of tobacco chewing along with the measurement of serum cotinine levels. Results: Oral tobacco led to high levels of cotinine in the majority of patients. There was an insignificant rise in heart rate, systolic and diastolic blood pressure following tobacco consumption. Baseline CFR (median 1.6, range 1.1–5.5) was low in tobacco chewers after PCI even after optimum FFR (0.9 ± 0.05) in the majority of patients suggesting abnormal microvascular hemodynamics (high IMR in 3 patients, overall median 14.2, range 7–36.2). However, there was no significant change in the estimated CFR or IMR values following tobacco chewing. One patient had bradycardia and hypotension which may be related to vagal reaction or acute nicotine poisoning. Conclusion: Tobacco chewers have abnormal coronary microcirculation hemodynamics even following a successful PCI. However, the coronary micocirculation and hemodynamics do not change acutely following tobacco chewing despite high serum cotinine concentrations.

Item Type:Article
Source:Copyright of this article belongs to Wolters Kluwer.
Keywords:Coronary Flow Reserve; Cotinine; Fractional Flow Reserve; Index of Microcirculatory Resistance; Oral Tobacco
ID Code:114590
Deposited On:01 Jun 2018 08:58
Last Modified:01 Jun 2018 08:58

Repository Staff Only: item control page