Influence of system parameters on the hysteresis characteristics of a horizontal Rijke tube

Gopalakrishnan, E. A. ; Sujith, R. I. (2014) Influence of system parameters on the hysteresis characteristics of a horizontal Rijke tube International Journal of Spray and Combustion Dynamics, 6 (3). pp. 293-316. ISSN 1756-8277

[img]
Preview
PDF
825kB

Official URL: http://journals.sagepub.com/doi/abs/10.1260/1756-8...

Related URL: http://dx.doi.org/10.1260/1756-8277.6.3.293

Abstract

The influence of system parameters such as heater power, heater location and mass flow rate on the hysteresis characteristics of a horizontal Rijke tube is presented in this paper. It is observed that a hysteresis zone is present for all the mass flow rates considered in the present study. A power law relation is established between the non-dimensional hysteresis width and the Strouhal number, defined as the ratio between convective time scale and acoustic time scale. The transition to instability in a horizontal Rijke tube is found to be subcritical in all the experiments performed in this study. When heater location is chosen as the control parameter, period-2 oscillations are found for specific values of mass flow rate and heater power.

Item Type:Article
Source:Copyright of this article belongs to SAGE Publications.
Keywords:Hysteresis; Subcritical Hopf Bifurcation; Rijke Tube; Period-2 Oscillations Wave–Turbulence Interactions
ID Code:109950
Deposited On:21 Dec 2017 10:55
Last Modified:21 Dec 2017 10:55

Repository Staff Only: item control page