Failure analysis of a hot extrusion die used for Al-Li alloy processing

Rama Murty, U. ; Avadhani, G. S. ; Dwarakadasa, E. S. (1992) Failure analysis of a hot extrusion die used for Al-Li alloy processing Bulletin of Materials Science, 15 (2). pp. 171-181. ISSN 0250-4707

[img]
Preview
PDF - Publisher Version
2MB

Official URL: http://www.ias.ac.in/j_archive/bms/15/2/171-182/vi...

Related URL: http://dx.doi.org/10.1007/BF02927443

Abstract

Al-Li alloys being developed as lighter, substitutes for conventional high strength Al alloys are to be processed by routine methods. During extrusion of a 8090 Al-Li alloy, the extrusion die container failed causing some alarm. This failed die container was analysed to examine if the failure was caused by interaction of Li diffusing out of Al-Li alloy with the carbides of die steel. The evidence, although not conclusive, is sufficient to exercise caution during such processing.

Item Type:Article
Source:Copyright of this article belongs to Indian Academy of Sciences.
Keywords:Al-Li Alloys; Extrusion; Die Failure; Diffusion; Li-Carbide Interaction