CFD simulation of heat transfer in a two-dimensional vertical enclosure

Ganguli, A. A. ; Pandit, A. B. ; Joshi, J. B. (2009) CFD simulation of heat transfer in a two-dimensional vertical enclosure Chemical Engineering Research and Design, 87 (5). pp. 711-727. ISSN 0263-8762

Full text not available from this repository.

Official URL: http://www.sciencedirect.com/science/article/pii/S...

Related URL: http://dx.doi.org/10.1016/j.cherd.2008.11.005

Abstract

In order to predict the variation in heat transfer coefficient setup by natural convection, independent CFD simulations have been performed for various tall slender vertical geometries (100 mm < H < 1000 mm) with varying gap widths (5 mm < L < 84.7 mm) and temperature differences (5 K < ΔT < 90 K) covering the ranges reported in the literature (Batchelor, G.K., 1954. Heat transfer by free convection across a closed cavity between vertical boundaries at different temperatures. Quart. Appl. Math., 12, 209-233; Newell, M.E., Schmidt, F.W., 1970. Heat transfer by laminar natural convection within rectangular enclosures. Trans. ASME C: J. Heat Transf., 92, 159-167; Yin, S.H., Wung, T.Y., Chen, K., 1978. Natural Convection in an air layer enclosed within rectangular cavities. Int. J. Heat Mass Transf., 21, 307-315; Elsherbiny, S.M., Raithby, G.D., Hollands K.G.T., 1982. Heat transfer by natural convection across vertical and inclined air layers. Trans. ASME J. Heat Transf., 104: 96-102; Lee, Y., Korpela, S., 1983. Multicellular natural convection in a vertical slot. J. Fluid Mech., 126, 91-124) and compared with their own experimental and numerical studies. A good agreement of Nusselt number (±10%) has been found between the CFD predictions and the literature data. Further, simulations were carried out for gap widths (5 mm ≤ L ≤ 25 mm), heights (100 mm ≤ H ≤ 1000 mm) (4 ≤ AR ≤ 200) and temperature differences (20 K ≤ ΔT ≤ 90 K, 5.99E + 02 ≤ Ra ≤ 3.15E + 05) and a correlation for the estimation of Nu has been proposed. The sensitivity analysis shows %deviation of heat transfer coefficient only in the range of ±10%. A generalized correlation based on all the above results encompassing the effect of height, gap width and temperature difference has also been proposed, which can be used to accurately estimate heat losses from a vertical air gap acting as an insulation.

Item Type:Article
Source:Copyright of this article belongs to Institution of Chemical Engineers.
Keywords:Natural Convection; Rectangular Slots; Correlation; Flow Patterns; Heat Transfer; CFD Simulation
ID Code:61053
Deposited On:13 Sep 2011 11:13
Last Modified:06 Jul 2012 06:26

Repository Staff Only: item control page