Comparative evaluation of strain controlled low cycle fatigue behaviour of solution annealed and prior cold worked 316L(N) stainless steel

Srinivasan, V. S. ; Sandhya, R. ; Valsan, M. ; Bhanu Sankara Rao, K. ; Mannan, S. L. (2004) Comparative evaluation of strain controlled low cycle fatigue behaviour of solution annealed and prior cold worked 316L(N) stainless steel International Journal of Fatigue, 26 (12). pp. 1295-1302. ISSN 0142-1123

Full text not available from this repository.

Official URL: http://linkinghub.elsevier.com/retrieve/pii/S01421...

Related URL: http://dx.doi.org/10.1016/j.ijfatigue.2004.05.003

Abstract

The effect of 20% prior cold work on low cycle fatigue (LCF) behaviour of type 316L(N) stainless steel (SS) was studied at 873 K by conducting total axial strain controlled tests in air with strain amplitudes in the range ±0.25% to ±1.0%. The cyclic deformation behaviour of 20% prior cold worked (PCW) material was compared with the LCF response of solution annealed (SA) alloy tested under similar conditions. The cyclic stress response (CSR) of 316L(N) SS in the PCW condition was characterized by a short period of hardening followed by prolonged softening prior to failure, whereas SA material exhibited a significant hardening regime followed by stress saturation. Interrupted tests on PCW material were carried out at different stages of CSR in order to determine the underlying mechanisms as reflected in substructural changes. The fatigue life in the solution annealed condition was similar to that of the PCW material at higher strain amplitudes of testing (≥±0.5%) while at lower strain amplitudes, the PCW material exhibited longer life.

Item Type:Article
Source:Copyright of this article belongs to Elsevier Science.
Keywords:Cyclic Hardening; Softening; Dynamic Strain Ageing; Recovery
ID Code:18300
Deposited On:17 Nov 2010 12:50
Last Modified:18 May 2011 05:58

Repository Staff Only: item control page