Mondal, N. K. ; et., al (2010) Performance and operation of the CMS electromagnetic calorimeter Journal of Instrumentation, 5 (3). T03010_1-T03010_24. ISSN 1748-0221
|
PDF
- Author Version
908kB |
Official URL: http://iopscience.iop.org/1748-0221/5/03/T03010
Related URL: http://dx.doi.org/10.1088/1748-0221/5/03/T03010
Abstract
The operation and general performance of the CMS electromagnetic calorimeter using cosmic-ray muons are described. These muons were recorded after the closure of the CMS detector in late 2008. The calorimeter is made of lead tungstate crystals and the overall status of the 75 848 channels corresponding to the barrel and endcap detectors is reported. The stability of crucial operational parameters, such as high voltage, temperature and electronic noise, is summarised and the performance of the light monitoring system is presented.
Item Type: | Article |
---|---|
Source: | Copyright of this article belongs to Institute of Physics. |
Keywords: | Calorimeters; Large Detector Systems for Particle and Astroparticle Physics |
ID Code: | 90099 |
Deposited On: | 04 May 2012 13:49 |
Last Modified: | 19 May 2016 04:25 |
Repository Staff Only: item control page