John, Bency ; Topkar, A. ; Vind, R. P. ; Inkar, A. L. ; Biswas, D. C. ; Saxena, A. ; Gupta, Y. K. ; Kailas, S. (2009) Charged particle identification by pulse shape discrimination with single-sided segmented silicon-pad detectors Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 609 (1). pp. 24-31. ISSN 0168-9002
Full text not available from this repository.
Official URL: http://www.sciencedirect.com/science/article/pii/S...
Related URL: http://dx.doi.org/10.1016/j.nima.2009.08.022
Abstract
A charged particle detector array consisting of 50 Si-CsI detector telescopes for study of heavy-ion reactions is under construction in BARC-TIFR Pelletron-LINAC facility. Single-sided segmented silicon-pad detectors of 300 µm thickness and 400 mm2 total active area have been fabricated for this purpose and their design parameters along with static and dynamic characteristics are presented. A low-cost solution for implementing the pulse-shape-based particle discrimination technique with the silicon-pad detectors has been demonstrated through in-beam measurements and the results obtained are presented.
Item Type: | Article |
---|---|
Source: | Copyright of this article belongs to Elsevier Science. |
Keywords: | Charged Particle Spectroscopy; Detector Array; Segmented Silicon Detectors; Static Characteristics; Pulse Shape Discrimination Technique; Fission Fragment Detection |