Arunmuthu, K. ; Arun Kumar, P. ; Saravanan, T. ; Philip, John ; Jayakumar, T. ; Baldev Raj, (2008) Image processing of radiographs of tube-to-tubesheet weld joints for enhanced detectability of defects Insight, 50 (6). pp. 298-303. ISSN 1354-2575
Full text not available from this repository.
Official URL: http://www.atypon-link.com/BINT/doi/abs/10.1784/in...
Related URL: http://dx.doi.org/10.1784/insi.2008.50.6.298
Abstract
This paper discusses the application of digital image processing, particularly Fourier space filters over the spatial filters, for enhanced detectability of defect features in the tube-to-tubesheet weld samples. The Butterworth band-pass filter is found to give optimal maximum signal-to-noise ratio (SNR) compared to other spatial and Fourier filters such as Sobel, Prewitt, Laplacian, Robert operator, ramp filter and Butterworth high-pass. The minimum pore size measurable using this approach is about 60 microns. Quantification of width of about 35 microns, for lack of fusion, is possible after applying the Butterworth band-pass filter. A flowchart has also been designed for regular application of digital image processing on radiographs of tube-to-tubesheet weld joints. The studies show that Butterworth band-pass filtering is ideal for enhanced evaluation of radiographs of tube-to-tubesheet joints with reliability and sensitivity.
Item Type: | Article |
---|---|
Source: | Copyright of this article belongs to British Institute of Non-Destructive Testing. |
ID Code: | 40652 |
Deposited On: | 24 May 2011 11:27 |
Last Modified: | 24 May 2011 11:27 |
Repository Staff Only: item control page